6 Design Elements of a Safe OR
By: Aorn Staff
Published: 8/19/2026
Original publish date March 27, 2019
The characteristic clutter in most ORs can be annoying, but research suggests such clutter can also disrupt the flow of people, equipment, supplies, and information, creating significant safety risks for surgical team members and patients.
Surgical suite design affects workflow efficiency, communication, environmental hygiene, staff safety, and patient outcomes. Evidence continues to demonstrate that room layout, equipment placement, lighting, visibility, and clutter reduction can influence perioperative team performance and the delivery of safe patient care.
One influential human-centered design project identified six characteristics that can help create safer and more ergonomic operating rooms. These principles remain relevant for organizations planning new construction, renovations, or smaller workflow and environmental improvements.
Understanding Safer Design Elements
Based on this research, these six key design characteristics were applied in a 579-square-foot high-fidelity OR prototype built at Clemson University’s architecture campus in Charleston, S.C.:
Increase Flexibility and Adaptability
A modular space was designed to be modified into a single corridor, clean core, or work core OR suite. The space offers varied uses such as an induction room, instrument processing room, or imaging control room.
The same principle of future flexibility was considered in providing surgical lights and booms that can be modified in response to changing needs, including surgical booms that can be reconfigured to accommodate gas, electric and data connections.Improve Movement and Flow
To prevent staff members from tripping over cables and bumping into each other or equipment, four established quadrants of the surgical suite were created to allow more adequate space for an anesthesia zone at the head of the surgical table, a circulation zone at the foot of the table, and sterile zones on both sides of the bed. This setup gave the circulating nurse more room to move a mobile workstation and maintain access to team members and the patient.
Storage in the room was placed within close proximity to team members, such as the circulating nurse and anesthesia professional, to minimize unnecessary movement and travel within the OR. The team also considered the location of doors to facilitate equipment movement and patient transfer while minimizing intrusions into the sterile field during procedures.Reduce Clutter
Physical features such as flush wall surfaces, recessed storage, and overhead booms for cable and tubing management reduced clutter and improved OR traffic flow.Decrease Microbial Load
Design features that support environmental cleaning and disinfection can help reduce contamination risks. Examples include minimizing difficult-to-clean horizontal surfaces, selecting finishes that support effective cleaning, reducing unnecessary touch points, and incorporating technologies that support environmental hygiene.Enhance Visibility and Communication
Integrated digital wall-mounted information displays placed in multiple locations on surgical booms and walls improved team members' access to information. This information can change throughout the procedure to support various phases of intraoperative care, including surgical checklists, views of the surgical site, and patient vital signs.
Integrated information displays and digital technologies also can support situational awareness by providing access to patient information, procedural data, imaging, checklists, and communication tools while minimizing workflow disruptions.Improve Healthy Lighting
Research shows that surgical team members are more satisfied when they have access to daylight and outside views while in the OR. Structural design allowed strategic access to daylight and outdoor views that could be controlled to accommodate light levels, glare, and privacy requirements.
Access to daylight, ergonomic workspaces, and design features that reduce physical strain may contribute to staff well-being, satisfaction, and retention while supporting safe patient care.
Making Changes
While major changes, such as increasing room size or relocating fixed storage or doors, may not be feasible in an existing OR, organizations can often make smaller changes that improve workflow and reduce disruptions.
"We found that angling the surgical bed significantly improved space usage and flow in the OR and resulted in fewer bed movements for different surgeries," Joseph said.
"The key is for teams to objectively observe their current workflows and identify where they are having challenges with movement and flow," Joseph said. "Simple changes to furniture placement and arrangement may help address some of these problems."
Updated Conclusion
Although complete surgical suite renovations may not be feasible for every facility, perioperative teams can often improve safety and efficiency through targeted changes to room configuration, equipment placement, storage locations, and workflow patterns. Applying human-centered design principles can help organizations create environments that support communication, reduce disruptions, and promote safe patient care.
Updated Member Resources
Free Resources for Members
Explore implementation resources that support the current AORN Guideline for Design and Maintenance of the Surgical Suite, including:
- Clinical FAQs
- Implementation tools and templates
- Guideline Quick Views
- Evidence and recommendations supporting surgical suite design
- Current education and continuing education resources related to surgical suite design and maintenance